Product Code : EL-M-11004
Quick Answer: The Inverted Fluorescence Microscope carries infinity plan fluor objectives from 4x to 40x, a 45 degree Siedentopf trinocular head with 100:0 and 80:20 light split, and a long-working-distance condenser that detaches quickly.
Last updated: October 2026
Key Features
Infinity plan fluor objectives: 4x, 10x, 20x and 40x.
Siedentopf trinocular head, 45 degrees, light split 100:0 and 80:20, interpupillary distance 48–76 mm.
WF 10x/22 mm diopter-adjustable eyepieces.
Mechanical stage 210 x 241 mm with 118 mm diameter round slide, attachable stage for 96-hole plates (travel 128 x 80 mm) and 54 mm culture dish holder.
LWD condenser, 72 mm working distance, or 95 mm without condenser for extra-high culture dishes.
Halogen 12V 30W Koehler transmitted light; low-position coaxial focus, coarse 42 mm and fine 0.2 mm per rotation, minimum reading 2 micron.
Technical Specifications
| Specification | Value |
|---|---|
| Objectives | Infinity plan fluor 4x, 10x, 20x, 40x |
| Head | Siedentopf trinocular, 45 degrees, 100:0 / 80:20 |
| Eyepieces | WF 10x/22 mm, diopter adjustable |
| Stage | 210 x 241 mm; 96-hole plate stage, travel 128 x 80 mm |
| Condenser | LWD, 72 mm (95 mm without condenser) |
| Light source | Halogen 12V 30W, Koehler |
| Focus | Coaxial; coarse 42 mm/rotation, fine 0.2 mm/rotation |
| Minimum focus reading | 2 micron |
About This Product
An inverted layout puts the objectives under the stage, so culture dishes and 96-hole plates can be examined from below. Removing the condenser opens the working distance from 72 mm to 95 mm for extra-high culture dishes, and the stage knob can be fitted on the left or the right. Colleges and TVET centres in Senegal, Colombia, Democratic Republic of the Congo, Yemen and Malaysia can source the Inverted Fluorescence Microscope from Educational Lab Equipments.
Frequently Asked Questions
Can the Inverted Fluorescence Microscope hold multi-well plates?
Yes. An attachable mechanical stage takes 96-hole plates with a moving range of 128 x 80 mm, and there is a 54 mm culture dish holder.
What objectives are fitted?
Infinity plan fluor objectives at 4x (NA 0.10, WD 18.5 mm), 10x, 20x and 40x (NA 0.75, WD 0.51 mm).
What is the working distance of the condenser?
72 mm with the condenser fitted, or 95 mm without it for extra-high culture dishes. The condenser is quickly detachable.
Related: Microscopes, Inverted Tissue Culture Microscope, Trinocular Inverted Tissue Culture Microscope, Digital Trinocular Microscope With LED Illumination.
For a quotation on the Inverted Fluorescence Microscope, contact Educational Lab Equipments.